MLAB


Module
mlab-module power-supp

TPS63036V01

Highly efficient buck-boost converter module (TPS63036V01) for stable power output in portable and low-power devices.

This is an open-source hardware design, one of the modules from the MLAB labolatory system.

TPS63036V01 - TPS63036-Based buck-boost converter

The TPS63036V01 module is a highly efficient, single-inductor, buck-boost converter designed to provide a stable output voltage from varying input voltages. It integrates the Texas Instruments TPS63036 chip, making it suitable for applications requiring a compact, efficient power solution.

TPS63036V01 top TPS63036V01 bottom

Features

  • Input Voltage Range: 1.8V to 5.5V
  • Output Voltage: 3.3V (adjustable between 1.2V and 5.5V)
  • Maximum Output Current: 600 mA
  • Operating Frequency: 2 MHz
  • High Efficiency: Up to 85% at 3.6V input and 500mA load
  • Compact Size: Miniature 3.0 × 3.0 mm footprint
  • Shielded Inductors: LPS3015 series for low DCR and excellent current handling

Components

TPS63036 Buck-Boost Converter

  • Manufacturer: Texas Instruments
  • Package: 8-ball, 1.854 mm × 1.076 mm wafer chip-scale package (YFG)
  • Description: The TPS63036 is a highly efficient single-inductor buck-boost converter. It supports both fixed and adjustable output voltages. The device operates with an input voltage range of 1.8V to 5.5V.

LPS3015 Series Shielded Inductors

  • Manufacturer: Coilcraft
  • Inductance Values: Range from 1.0 µH to 330 µH
  • DCR (max): 0.075 to 23.0 ohms
  • Current Rating: Up to 2.35A
  • SRF (min): 9 MHz
  • Dimensions: 3.0 × 3.0 mm footprint, less than 1.5 mm tall

Setup Instructions

  1. Input Connection: Connect the input power supply between on input header. Ensure the input voltage is between 1.8V and 5.5V.
  2. Output Connection: Connect the load to output header.
  3. Enable/Disable: Use jumper SV1 to enable or disable the TPS63036.
  4. Power-Saving Mode: Use jumper SV6 to enable (PWM/PSM) or disable (PWM) the power-saving mode.

Performance Specifications

Parameter Condition Min Typ Max Unit
Input Voltage 1.8 5.5 V
Output Voltage Vin = 4.2V, Iout = 500mA 3.2 3.3 3.4 V
Output Current Vin = 3.6V 0 600 mA
Operating Freq. 2000 kHz
Efficiency 3.6V in, 500mA load 85 %
Output Ripple 3.6V in, 500mA load 25 mV

Additional Resources

Contact

For support, contact MLAB at support@mlab.cz.